Every year operators are hurt or killed by equipment that "was off" — a pump that restarted while a hand was in the casing, a valve that was opened by a coworker who never saw the tag, a panel that was assumed dead. Lockout/tagout (LOTO) is the discipline that makes "off" mean off, and it is tested on every water, wastewater and collection exam. This guide takes you from the OSHA energy-control standard (29 CFR 1910.147) through group lockout, stored energy, electrical grounding, GFCIs and arc flash, and tells you exactly when to stop and call a qualified electrician.
1. Why hazardous energy kills
OSHA's energy-control standard applies to servicing and maintenance of machines and equipment where unexpected energization, start-up, or release of stored energy could injure an employee (1910.147(a)(1)(i)). In a treatment plant or collection system that covers nearly everything you touch